Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 13.661
Filtrar
1.
Clin Orthop Surg ; 16(2): 210-216, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562629

RESUMO

Background: As the population ages, the rates of hip diseases and fragility fractures are increasing, making total hip arthroplasty (THA) one of the best methods for treating elderly patients. With the increasing number of THA surgeries and diverse surgical methods, there is a need for standard evaluation protocols. This study aimed to use deep learning algorithms to classify THA videos and evaluate the accuracy of the labelling of these videos. Methods: In our study, we manually annotated 7 phases in THA, including skin incision, broaching, exposure of acetabulum, acetabular reaming, acetabular cup positioning, femoral stem insertion, and skin closure. Within each phase, a second trained annotator marked the beginning and end of instrument usages, such as the skin blade, forceps, Bovie, suction device, suture material, retractor, rasp, femoral stem, acetabular reamer, head trial, and real head. Results: In our study, we utilized YOLOv3 to collect 540 operating images of THA procedures and create a scene annotation model. The results of our study showed relatively high accuracy in the clear classification of surgical techniques such as skin incision and closure, broaching, acetabular reaming, and femoral stem insertion, with a mean average precision (mAP) of 0.75 or higher. Most of the equipment showed good accuracy of mAP 0.7 or higher, except for the suction device, suture material, and retractor. Conclusions: Scene annotation for the instrument and phases in THA using deep learning techniques may provide potentially useful tools for subsequent documentation, assessment of skills, and feedback.


Assuntos
Artroplastia de Quadril , Aprendizado Profundo , Fraturas Ósseas , Prótese de Quadril , Humanos , Idoso , Artroplastia de Quadril/métodos , Acetábulo/cirurgia , Fraturas Ósseas/cirurgia , Fêmur/cirurgia , Estudos Retrospectivos
2.
Clin Orthop Surg ; 16(2): 201-209, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562642

RESUMO

Background: Proximal-distal mismatch has emerged as a prominent concern in Dorr type A femoral morphology, prompting the exploration of short stems as promising alternatives to conventional stems. This study aimed to evaluate clinical and radiographic outcomes of total hip arthroplasty (THA) using short femoral stems in Dorr type A proximal femoral morphology with a minimum follow-up of 5 years. Methods: Patients with short femoral stems in Dorr type A between 2011 and 2017 were included. Patients with the Short Modular Femoral (SMF) stem and Metha stem were recruited and patients with a shortened tapered stem (Tri-Lock BPS) were matched by propensity score matching based on age, sex, body mass index, calcar to canal ratio, and diagnosis. Patient-reported outcomes and the presence of thigh pain were assessed at 5 years postoperatively. Revision rate, complication rate, and radiographic outcomes were also assessed and compared. Results: Twenty-two cases (81%) in the SMF stem and 43 cases (65%) in the Metha stem had more than 5 years of follow-up data available. The SMF stem showed a higher failure rate than the other 2 groups, with 18% requiring revision surgery in the SMF stem compared to 4.6% in the Metha stem, and 2.3% in the Tri-Lock BPS. The SMF stem showed considerable complications such as stem position change and lateral cortical hypertrophy with inferior clinical outcomes than the other 2 stem groups. When the Metha stem and the Tri-Lock BPS groups were compared, more intraoperative fractures were observed in the Metha stem, whereas stress shielding and anterior thigh pain were significantly more prevalent in the Tri-Lock BPS. Conclusions: The SMF stem might be less reliable than previously reported, showing a high failure rate and increased radiologic complications. Thus, its use for THA in Dorr Type A femurs needs caution. On the other hand, the Metha stem showed comparable outcomes to the shortened tapered Tri-Lock BPS.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Sobrevivência , Desenho de Prótese , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Reoperação , Dor/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Seguimentos
3.
J Am Acad Orthop Surg ; 32(9): 373-380, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38639649

RESUMO

Pediatric femur fractures in children aged 5 to 11 years are typically classified as length-stable versus length-unstable. For length-stable fracture patterns, there is frequent consensus among pediatric orthopaedic specialists regarding the appropriateness of flexible intramedullary nails, submuscular plates (SMP), or lateral-entry rigid intramedullary nails (LE-RIMN). With length-unstable fracture patterns, however, the decision is more complex. Age, weight, fracture pattern, fracture location, surgical technique, surgeon experience, several implant-specific details, and additional factors are all important when choosing between flexible intramedullary nail, SMP, and LE-RIMN. These familiar methods of fixation may all be supported by conflicting and sometimes heterogeneous data. When planning to treat length-unstable fractures in young children, surgeons should understand evidence-based details associated with each implant and how each patient-specific scenario affects perioperative decisions.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Humanos , Criança , Pré-Escolar , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/métodos , Pinos Ortopédicos , Placas Ósseas , Fêmur/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
4.
PLoS One ; 19(4): e0299996, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38603691

RESUMO

Maintaining post-operative mechanical stability is crucial for successfully healing intertrochanteric fractures treated with the Proximal Femoral Nail Antirotation (PFNA) system. This stability is primarily dependent on the bone mineral density (BMD) and strain on the fracture. Current PFNA failure analyses often overlook the uncertainties related to BMD and body weight (BW). Therefore, this study aimed to develop a probabilistic model using finite element modeling and engineering reliability analysis to assess the post-operative performance of PFNA under various physiological loading conditions. The model predictions were validated through a series of experimental test. The results revealed a negative nonlinear relationship between the BMD and compressive strain. Conversely, the BW was positively and linearly correlated with the compressive strain. Importantly, the compressive strain was more sensitive to BW than to BMD when the BMD exceeded 0.6 g/cm3. Potential trabecular bone compression failure is also indicated if BMD is equal to or below 0.15 g/cm3 and BW increases to approximately 2.5 times the normal or higher. This study emphasizes that variations in the BMD significantly affect the probability of failure of a PFNA system. Thus, careful planning of post-operative physical therapy is essential. For patients aged > 50 years restrictions on high-intensity activities are advised, while limiting strenuous movements is recommended for those aged > 65 years.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Quadril , Humanos , Fixação Intramedular de Fraturas/métodos , Reprodutibilidade dos Testes , Pinos Ortopédicos , Fraturas do Quadril/cirurgia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
5.
JBJS Case Connect ; 14(2)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38635784

RESUMO

CASE: We describe the unique case of a 20-year-old man with a history of Legg-Calve-Perthes disease, hip dysplasia, and osteochondral fragmentation of the medial femoral head. We performed arthroscopic femoroplasty and femoral head allografting, followed by a valgus-producing derotational femoral osteotomy (DFO) and periacetabular osteotomy (PAO). At 1-year follow-up, the patient achieved osseous union and complete femoral head healing with return to his active hobbies. CONCLUSION: We describe the successful utilization of arthroscopic allografting for medial femoral head osteochondral fragmentation. To our knowledge, this is the first report on femoral head arthroscopic allografting before DFO and PAO.


Assuntos
Cabeça do Fêmur , Doença de Legg-Calve-Perthes , Masculino , Humanos , Adulto Jovem , Adulto , Cabeça do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/cirurgia , Doença de Legg-Calve-Perthes/diagnóstico por imagem , Doença de Legg-Calve-Perthes/cirurgia , Doença de Legg-Calve-Perthes/complicações , Osteotomia , Fêmur/cirurgia , Progressão da Doença , Aloenxertos
6.
J Orthop Surg Res ; 19(1): 206, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561763

RESUMO

BACKGROUND: Reports show a high complication rate when starting with the Direct Anterior Approach (DAA) in a supine position for hip arthroplasty. The DAA with the patient in lateral decubitus position may avoid this problem because it supposedly provides better visibility, especially on the femoral side. However, this approach did show a rather high complication rate during the adoption of the approach at 1 year follow up in our previous report. We were interested what the overall 7 year survival estimate would be and whether improvement could be seen with growing experience. METHODS: A cohort of patients undergoing total hip arthroplasty right from the start of applying the DAA in lateral decubitus position was analysed. RESULTS: In total 175 hip prostheses (162 patients) were evaluated. The 7-year survival estimate was 95.1%, 95 CI: 91.8-98.4%. In 6 of 8 revisions there was aseptic loosening of the stem. By dividing the cohort into 3 consecutive groups in time we did not see a significantly improving revision rate. CONCLUSIONS: In our experience, the adoption of the direct anterior approach in lateral decubitus position caused a relatively low 7-year survival estimate without an apparent decrease with growing experience, however given the low number of cases further research is needed to investigate the long-term risk of adopting a new approach.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Estudos Retrospectivos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Fêmur/cirurgia , Reoperação
7.
JBJS Case Connect ; 14(2)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38579104

RESUMO

CASE: We describe the surgical management of a girl with dwarfism and congenital spondyloepiphyseal dysplasia, who presented in adolescence with coxa vara and bilateral pseudarthrosis between the femoral neck and the diaphysis, with asymmetric distal migration at both sites and leg length discrepancy. The patient at 16 years underwent valgus osteotomy in situ and femoral neck fixation in the left hip. The right hip was operated 19 months later. CONCLUSION: Hip dysplasia is common in spondyloepiphyseal dysplasia, but a debilitating nontraumatic bilateral pseudarthrosis at the base of the femoral neck has not been previously reported. Valgus corrective osteotomies of the femur in situ led to union and allowed the patient to walk.


Assuntos
Coxa Vara , Osteocondrodisplasias , Pseudoartrose , Feminino , Humanos , Adolescente , Colo do Fêmur/cirurgia , Osteocondrodisplasias/complicações , Osteocondrodisplasias/diagnóstico por imagem , Osteocondrodisplasias/cirurgia , Pseudoartrose/diagnóstico por imagem , Pseudoartrose/cirurgia , Fêmur/cirurgia , Coxa Vara/diagnóstico por imagem , Coxa Vara/cirurgia
8.
IEEE J Transl Eng Health Med ; 12: 340-347, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38606389

RESUMO

OBJECTIVE: Cemented total hip arthroplasty (THA) demonstrates superior survival rates compared to uncemented procedures. Nevertheless, most younger patients opt for uncemented THA, as removing well-fixed bone cement in the femur during revisions is complex, particularly the distal cement plug. This removal procedure often increases the risk of femoral fracture or perforation, haemorrhage and weakening bone due to poor drill control and positioning. Aim of this study was to design a novel drill guide to improve drill positioning. METHODS AND PROCEDURES: A novel orthopaedic drill guide was developed, featuring a compliant centralizer activated by a drill guide actuator. Bone models were prepared to assess centralizing performance. Three conditions were tested: drilling without guidance, guided drilling with centralizer activation held, and guided drilling with centralizer activation released. Deviations from the bone centre were measured at the entry and exit point of the drill. RESULTS: In the centralizing performance test, the drill guide significantly reduced drill hole deviations in both entry and exit points compared to the control ([Formula: see text]). The absolute deviation on the exit side of the cement plug was 10.59mm (SD 1.56) for the 'No drill guide' condition, 3.02mm (SD 2.09) for 'Drill guide - hold' and 2.12mm (SD 1.71) for 'Drill guide - release'. The compliant drill guide centralizer significantly lowered the risk of cortical bone perforation during intramedullary canal drilling in the bone models due to better control of the cement drill position. Clinical and Translational Impact Statement: The drill guide potentially reduces perioperative risks in cemented femoral stem revision. Future research should identify optimal scenarios for its application.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Ortopedia , Humanos , Artroplastia de Quadril/efeitos adversos , Reoperação , Fêmur/cirurgia , Cimentos Ósseos/uso terapêutico
9.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 498-504, 2024 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-38632073

RESUMO

Objective: To review the concept and methods of femoral bone tunnel positioning in anterior cruciate ligament (ACL) reconstruction, in order to provide a reference for clinical treatment. Methods: The relevant literature on the concept and methods of femoral bone tunnel positioning in ACL reconstruction in domestic and international research was extensively reviewed. Results: The position of the femoral bone tunnel is a key factor in determining the prognosis of ACL reconstruction. The concept of femoral bone tunnel positioning in ACL reconstruction has experienced isometric reconstruction, anatomical reconstruction, Ribbon-like theory, I.D.E.A.L. theory, and nearly isometric reconstruction theory. The femoral bone tunnel positioning technique is also changing with the in-depth study of the anatomy and biomechanics of the ACL, and each bone tunnel positioning technique has its own advantages and disadvantages. Over-The-Top technique is now mainly used for ACL revision; the clock-face positioning method is basically no longer applicable due to the large error, poor stability, and low retrievability; the bone landmarks positioning method (the lateral condyle of the femur's Resident's ridge and bifurcation ridge, and the the apex of the deep cartilage), which is now mostly used clinically due to the more constant anatomical landmarks. The quadrant method under X-ray fluoroscopy is more cumbersome to implement intraoperatively, so it is mainly used for academic research; computer navigation-assisted positioning has gradually become popular in recent years, which is highly accurate, avoids the influence of human factors on the positioning of the bone tunnel, and has a very good prospect of application; three-dimensional printing-assisted positioning technology, which is accurate in positioning, with a high degree of reproducibility and a short learning curve. Conclusion: The concept of femoral bone tunnel positioning for ACL reconstruction has undergone several evolutions, reflecting the deepening of the understanding of ACL and the improvement of the clinical results of reconstruction. The precision, personalization, and intelligence of positioning techniques are the focus of current and future development.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Humanos , Tíbia/cirurgia , Reprodutibilidade dos Testes , Fêmur/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Fenômenos Biomecânicos , Lesões do Ligamento Cruzado Anterior/cirurgia , Articulação do Joelho/cirurgia
10.
J Orthop Surg Res ; 19(1): 246, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632565

RESUMO

Background Tunnel placement is a key step in anterior cruciate ligament (ACL) reconstruction. The purpose of this study was to evaluate the accuracy of bone tunnel drilling in arthroscopic ACL reconstruction assisted by a three-dimensional (3D) image-based robot system. Methods Robot-assisted ACL reconstruction was performed on twelve freshly frozen knee specimens. During the operation, three-dimensional images were used for ACL bone tunnel planning, and the robotic arm was used for navigation and drilling. Twelve patients who underwent traditional arthroscopic ACL reconstruction were included. 3D computed tomography was used to measure the actual position of the ACL bone tunnel and to evaluate the accuracy of the robotic and traditional ACL bone tunnel. Results On the femoral side, the positions of robotic and traditional surgery tunnels were 29.3 ± 1.4% and 32.1 ± 3.9% in the deep-to-shallow direction of the lateral femoral condyle (p = 0.032), and 34.6 ± 1.2% and 21.2 ± 9.4% in the high-to-low direction (p < 0.001), respectively. On the tibial side, the positions of the robotic and traditional surgical tunnels were located at 48.4 ± 0.9% and 45.8 ± 2.8% of the medial-to-lateral diameter of the tibial plateau (p = 0.008), 38.1 ± 0.8% and 34.6 ± 6.0% of the anterior-to-posterior diameter (p = 0.071), respectively. Conclusions In this study, ACL reconstruction was completed with the assistance of a robot arm and 3D images, and the robot was able to drill the bone tunnel more accurately than the traditional arthroscopic ACL reconstruction.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Robótica , Humanos , Imageamento Tridimensional , Tomografia Computadorizada por Raios X , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Fêmur/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Lesões do Ligamento Cruzado Anterior/cirurgia
11.
PLoS One ; 19(4): e0296300, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38635518

RESUMO

OBJECTIVE: This study aimed to compare the stability and mechanical properties of the double chevron-cut (DCC) and biplanar (BP) distal femoral osteotomy (DFO) techniques, along with analyzing their respective contact surface areas. METHODS: Biomechanical testing was performed using sawbone and 3D modeling techniques to assess axial and torsional stability, torsional stiffness, and maximum torque of both osteotomy configurations. Additionally, 3D models of the sawbone femur were created to calculate and compare the contact surface area of the DCC, BP, and conventional single-plane DFO techniques. RESULTS: Axial stiffness and maximum strength did not significantly differ between the two osteotomy techniques. However, in terms of torsional properties, the DCC technique exhibited superior torsional stiffness compared to the BP group (27 ± 7.7 Nm/° vs. 4.5 ± 1.5 Nm/°, p = 0.008). Although the difference in maximum torque did not reach statistical significance (63 ± 10.6 vs. 56 ± 12.1, p = 0.87), it is noteworthy that the DCC group sawbone model exhibited fracture in the shaft region instead of at the osteotomy site. Therefore, the actual maximum torque of the DCC construct may not be accurately reflected by the numerical values obtained in this study. The contact surface area analysis revealed that the BP configuration had the largest contact surface area, 111% larger than that of the single-plane configuration. but 60% of it relied on the less reliable axial cut. Conversely, the DCC osteotomy offered a 31% larger contact surface area than the single-plane configuration, with both surfaces being weight-bearing. CONCLUSION: The DCC osteotomy exhibited superior mechanical stability, showing improved rotational stiffness and maximum torque when compared to the BP osteotomy. Although the BP osteotomy resulted in a larger contact surface area than the DCC osteotomy, both were larger than the conventional single-plane configuration. In clinical practice, both the DCC and BP techniques should be evaluated based on patient-specific characteristics and surgical goals.


Assuntos
Fraturas Ósseas , Osteotomia , Humanos , Osteotomia/métodos , Fêmur/cirurgia , Torque , Extremidade Inferior , Fenômenos Biomecânicos
12.
Microsurgery ; 44(4): e31172, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38651631

RESUMO

BACKGROUND: Post-oncologic surgical reconstruction of lower limbs in pediatrics remains a challenging topic. Microsurgical techniques allow reconstructions of large bony defects. The use of vascularized fibular flap with allograft has proven to be an ideal biologic construct. We aim to assess the success rate of this operation, including flap survival, bony union, weight-bearing ambulation, and complications in a long-term follow-up in our case series compared to the literature. PATIENTS AND METHODS: Our case-series includes 18 femoral resections (9 osteosarcomas, 8 Ewing sarcoma, and 1 desmoid tumor) and 15 tibial resections (10 osteosarcoma, 4 Ewing sarcoma, and 1 Malignant Fibrous Histiocytoma). We collected patients' demographics, type of tumor, type of resection, defect size, fibula-flap length, method of fixation, anastomosis site, follow-up data, complications, and their management. All survivals were examined by X-ray and CT-scan to evaluate the morphological changes of the vascularized fibula and follow-up. The functional evaluation was performed by the 30-point Musculoskeletal Tumor Society Rating Score (MSTS) for the lower limb (Enneking et al., Clinical Orthopaedics and Related Research 1993(286):241-246). RESULTS: The mean age of the femur resection patients' group was 11.2 years with a mean defect size of 14 cm and a mean length of the fibular flap of 18 cm; for the tibia the mean age was 12 years with a mean defect size of 14 cm and a mean length of the fibular flap of 16.6 cm. The overall survival of the reconstructions at 5 years follow-up was 17 out 18 cases for the femur and 13 out of 15 cases for the tibia. MSTS score was 28.2 for the femur and 23.7 for the tibia. The average time of union of the fibula was seen after 5 months, while allograft consolidation was observed around 19.7 months. The mean time of follow-up was 144.5 months for the femur and 139.2 months for the tibia. The complication rate observed was 7 out of 18 for the femur and 7 out of 15 for the tibia reconstructions. CONCLUSIONS: The viability of the fibula is a cornerstone in the success of reconstruction as well as the successful management of complications in intercalary defects after tumor resection in pediatrics to restore good functionality. Our results are in line with those reported in the literature in terms of overall complication rates. The high primary union of allograft, the high MSTS score obtained, and the low rate of severe complications reflect the mechanical role of this reconstructive technique over a long follow-up.


Assuntos
Neoplasias Ósseas , Fíbula , Microcirurgia , Procedimentos de Cirurgia Plástica , Tíbia , Humanos , Criança , Fíbula/transplante , Fíbula/irrigação sanguínea , Masculino , Feminino , Neoplasias Ósseas/cirurgia , Microcirurgia/métodos , Procedimentos de Cirurgia Plástica/métodos , Adolescente , Tíbia/cirurgia , Estudos Retrospectivos , Fêmur/cirurgia , Fêmur/transplante , Seguimentos , Resultado do Tratamento , Transplante Ósseo/métodos , Pré-Escolar , Retalhos de Tecido Biológico/irrigação sanguínea , Retalhos de Tecido Biológico/transplante , Aloenxertos , Sarcoma de Ewing/cirurgia , Retalhos Cirúrgicos/irrigação sanguínea , Retalhos Cirúrgicos/transplante , Sobrevivência de Enxerto
13.
PLoS One ; 19(4): e0300956, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38630711

RESUMO

Increasing the stem size during surgery is associated with a higher incidence of intraoperative periprosthetic fractures in cementless total hip arthroplasty with fully coated tapered wedge stems, especially in femurs of Dorr type A. If in contrast a stem is implanted and sufficient primary stability is not achieved, such preventing successful osseointegration due to increased micromotions, it may also fail, especially if the stem is undersized. Stem loosening or periprosthetic fractures due to stem subsidence can be the consequence. The adaptation of an established stem design to femurs of Dorr type A by design modifications, which increase the stem width proximally combined with a smaller stem tip and an overall shorter stem, might reduce the risk of distal locking of a proximally inadequately fixed stem and provide increased stability. The aim of this study was to investigate whether such a modified stem design provides improved primary stability without increasing the periprosthetic fracture risk compared to the established stem design. The established (Corail, DePuy Synthes, Warsaw, IN, US) and modified stem designs (Emphasys, DePuy Synthes, Warsaw, IN, US) were implanted in cadaveric femur pairs (n = 6 pairs) using the respective instruments. Broaching and implantation forces were recorded and the contact areas between the prepared cavity and the stem determined. Implanted stems were subjected to two different cyclic loading conditions according to ISO 7206-4 using a material testing machine (1 Hz, 600 cycles @ 80 to 800 N, 600 cycles @ 80 to 1600 N). Translational and rotational relative motions between stem and femur were recorded using digital image correlation. Broaching and implantation forces for the modified stem were up to 40% higher (p = 0.024), achieving a 23% larger contact area between stem and bone (R2 = 0.694, p = 0.039) resulting in a four times lower subsidence during loading (p = 0.028). The slight design modifications showed the desired effect in this in-vitro study resulting in a higher primary stability suggesting a reduced risk of loosening. The higher forces required during the preparation of the cavity with the new broaches and during implantation of the stem could bare an increased risk for intraoperative periprosthetic fractures, which did not occur in this study.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Prótese de Quadril/efeitos adversos , Fraturas Periprotéticas/epidemiologia , Desenho de Prótese , Artroplastia de Quadril/efeitos adversos , Osseointegração , Fêmur/cirurgia , Reoperação/efeitos adversos , Estudos Retrospectivos
14.
BMC Musculoskelet Disord ; 25(1): 312, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649874

RESUMO

BACKGROUND: Hip offset, version, and length are interdependent femoral variables which determine stability and leg length. Balancing these competing variables remains a core challenge in hip arthroplasty. The potential benefits of modular femoral stems have been overshadowed by higher rates of failure. The objective of this study was to assess the survivorship of a unique dual-modular femoral stem at an average 15-year follow-up period. METHODS: The records of all patients with osteoarthritis who underwent primary total hip arthroplasty with this device between 2004-2009 were reviewed. There were no exclusions for BMI or other factors. We examined the data with Kaplan-Meier survival analysis. The primary endpoint for survival was mechanical failure of the modular neck-body junction. RESULTS: The survivorship of this device in 172 subjects was 100% with none experiencing mechanical failure of the modular junction at an average of 15 years. 60 patients died of causes unrelated to their THA and 9 patients were lost to follow-up. There were three early (≤ 12 months) dislocations (1.7%), and seven total dislocations (4.1%). 16 patients underwent reoperations during the follow-up period, none for any complication of the modular junction. Radiographic results showed well-fixed femoral stems in all cases. There were no leg length discrepancies of greater than 10 mm, and 85% were within 5 mm. CONCLUSION: There were no mechanical failures of the modular junction in any of the subjects over the average 15-year period, demonstrating that this dual-modular design is not associated with increased failure rates. We achieved a 1.7% early dislocation rate and a 4.1% total dislocation rate without any clinically significant leg length discrepancies.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Humanos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Seguimentos , Osteoartrite do Quadril/cirurgia , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Estimativa de Kaplan-Meier , Reoperação/estatística & dados numéricos , Fêmur/cirurgia , Fêmur/diagnóstico por imagem , Fatores de Tempo
15.
Sci Rep ; 14(1): 7089, 2024 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-38528078

RESUMO

The purpose of this study is to evaluate the efficacy of plate augmentation and hybrid bone grafting for treating atrophic nonunion of the femur with original intramedullary nail retained in situ.In this study, 36 patients with atrophic nonunion of the femur who underwent surgery using the technique of plate augmentation and a hybrid bone grafting while retaining the original intramedullary nail in situ in Xi'an Honghui Hospital from January 2019 to December 2021 were enrolled. 28 patients who met the inclusion and exclusion criteria were ultimately included in the study. These 28 patients, consisting of 20 males and 8 females with a mean age of 38 years, were evaluated based on factors such as operation time, intraoperative blood loss, the average hospitalization days. Additionally, the results and function of these patients were evaluated by union time, Wu's scores of limb function and incidence of serious complications.All 28 patients achieved bone union at the 12 month follow-up, with an average follow-up time of 14.6 ± 4.2 months.The average operation time was 68.3 ± 11.2 min, and the average intraoperative blood loss was 140 ± 22.6 ml. Patients were hospitalized for an average of 5.8 ± 1.1 days. Full clinical and radiological bone union was achieved on average at 5.1 ± 1.9 months. The mean value of Wu's scores at the 12 month follow-up was significantly higher than before the operation. Limb function was excellent in 27 patients and good in one patient at the 12 month follow-up. However, five patients experienced the lower limb vein thrombosis, including one deep vein thrombosis and four lower limb intermuscular vein thromboses. One patient had a superficial infections of the surgical incision site, while three patients reported pain and numbness where their iliac bone graft was extracted at the 12 month follow-up. The technique of plate augmentation and hybrid bone grafting, combined with retaining the original intramedullary nail in situ has been shown to be a safe, effective, simply and standardizable practice for treating atrophic femoral nonunion with an intact original IMN fixation.


Assuntos
Fixação Intramedular de Fraturas , Fraturas não Consolidadas , Masculino , Feminino , Humanos , Adulto , Transplante Ósseo/métodos , Perda Sanguínea Cirúrgica , Fixação Intramedular de Fraturas/métodos , Pinos Ortopédicos/efeitos adversos , Fraturas não Consolidadas/cirurgia , Resultado do Tratamento , Fêmur/cirurgia , Extremidade Inferior , Estudos Retrospectivos , Consolidação da Fratura
16.
Acta Orthop Traumatol Turc ; 58(1): 39-44, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38525509

RESUMO

OBJECTIVE: The aim of this study was to evaluate the posterior condylar angle (PCA) and condylar twist angle (CTA) of the distal femur in the Turkish population and its concordance with the current standard prosthesis guides used in total knee arthroplasty (TKA). METHODS: Two hundred and forty knees of 120 Turkish subjects (60 male and 60 female) were included in this study. PCA, CTA, femoral mediolateral lengths (fML), medial femoral anteroposterior lengths (fMAP), lateral femoral anteroposterior lengths (fLAP), distances between the trochlear groove and fMAP (DBTG-fMAP), distances between the trochlear groove and fLAP (DBTG-fLAP), medial posterior condylar cartilage thickness (MPCCT) and lateral posterior condylar cartilage thicknesses (LPCCT) were measured on magnetic resonance imaging (MRI). RESULTS: The median CTA was 7° (range: 0°-13.0°) and the median PCA was 4° (range 0°-11.0°) (P < .0001). The median fML was 79.5 mm (range: 65.7-98.9). The median length of the fMAP was 58.2 mm (range: 46.8-69.0) and the median length of fLAP was 58.2 mm (range: 48.4-73.0). The DBTG-fMAP was 15.2 mm (range: 5.2-23.2), and DBTG-fLAP length was 21.9mm (range: 16.4-29.4). The median MPCCT and LPCCT were 2.4 mm (range: 1.6-3.6) and 2.3 mm (range: 1.2-2.8), respectively. The intraclass correlation coefficient for quantifying interobserver and intraobserver reliability showed excellent agreement regarding the PCA and CTA. CONCLUSION: This study has shown us that PCA and CTA may be higher in the Turkish population. Although it is not known whether these results have any clinical utility, it may be useful for surgeons to keep this in mind to prevent femoral component malposition. LEVEL OF EVIDENCE: Level IV, Diagnostic Study.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Masculino , Feminino , Artroplastia do Joelho/métodos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Reprodutibilidade dos Testes , Fluormetolona , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Osteoartrite do Joelho/cirurgia
17.
J Int Med Res ; 52(3): 3000605241240946, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38534086

RESUMO

BACKGROUND: To compare the biomechanical stability of a novel, C-shaped nickel-titanium shape memory alloy (SMA) implant (C-clip) with traditional cerclage wiring in the fixation of a Vancouver B1 (VB1) periprosthetic femoral fracture (PFF). METHODS: In total, 18 synthetic femoral fracture models were constructed to obtain unstable VB1 fracture with an oblique fracture line 8 cm below the lesser trochanter. For each model, the distal portion was repaired using a 10-hole locking plate and four distal bi-cortical screws. The proximal portion was repaired using either three, threaded cerclage wirings or three, novel C-shaped implants. Specimens underwent biomechanical testing using axial compression, torsional and four-point bending tests. Each test was performed on three specimens. RESULTS: The C-clip was statistically significantly stronger (i.e., stiffer) than cerclage wiring in the three biomechanical tests. For axial compression, medians (ranges) were 39 (39-41) and 35 (35-35) N/mm, for the C-clip and cerclage wiring, respectively. For torsion, medians (ranges) were, 0.44 (0.44-0.45) and 0.30 (0.30-0.33) N/mm for the C-clip and cerclage wiring, respectively. For the four-point bending test, medians (ranges) were 39 (39-41) and 28 (28-31) N/mm; for the C-clip and cerclage wiring, respectively. CONCLUSION: Results from this small study show that the novel, C-shaped SMA appears to be biomechanically superior to traditional cerclage wiring in terms of stiffness, axial compression, torsion and four-point bending, and may be a valuable alternative in the repair of VB1 PFF. Further research is necessary to support these results.


Assuntos
Fraturas do Fêmur , Fraturas Periprotéticas , Humanos , Ligas de Memória da Forma , Fraturas do Fêmur/cirurgia , Fêmur/cirurgia , Fraturas Periprotéticas/cirurgia , Fixação Interna de Fraturas/métodos , Placas Ósseas , Fenômenos Biomecânicos
18.
Knee Surg Sports Traumatol Arthrosc ; 32(4): 915-928, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38426570

RESUMO

PURPOSE: The relationship between constitutional coronal alignment and implant positioning on trochlear groove restoration in total knee arthroplasty (TKA) is poorly understood. This study aimed to determine whether the choice of alignment philosophy significantly affects the restoration of the trochlea groove. METHODS: Sixty-one imageless robotic TKAs performed by a single orthopaedic surgeon were retrospectively reviewed. In each case, the entire native trochlea was digitized to generate the native femoral anatomy, and implants were planned according to a functional alignment (FA) technique. Final implant position was recorded using the validated bone resection planes from the navigation system. Simulated femoral component positions were generated according to previously described alignment techniques: mechanical alignment (MA), gap balancing (GB), kinematic alignment (KA), restricted kinematic alignment (rKA) and restricted inverse kinematic alignment (riKA). Trochlear angle (TA), trochlear under/overstuffing and mediolateral sulcus offset were compared between the six simulated alignment techniques, as well as the final implanted technique. Further analyses investigated the effect of preoperative coronal alignment on trochlear position. Comparisons were assessed with an analysis of variance and Welch's t-tests or Wilcoxon's rank-sum tests with Bonferroni corrections. RESULTS: The implanted and simulated techniques all resulted in greater TA valgus compared to the native groove (p < 0.001). The implanted technique, KA and rKA were closer to the native TA than GB, MA and riKA (p > 0.001). All alignment philosophies understuffed the native trochlea groove. KA and rKA understuffed less than all other techniques (p < 0.001), and GB understuffed more than all other techniques (p < 0.001). In extension, all techniques shifted the trochlear sulcus laterally, while in flexion, they medialized it. These effects were most prominent in GB and MA. CONCLUSION: Personalized alignment techniques such as KA and rKA, which consider variations in individual anatomy, best restore the native patellar groove compared to systematic alignment techniques when using a standardized femoral component. LEVEL OF EVIDENCE: Level III, retrospective review.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Estudos Retrospectivos , Fêmur/cirurgia , Fenômenos Biomecânicos , Osteoartrite do Joelho/cirurgia
19.
Knee Surg Sports Traumatol Arthrosc ; 32(4): 978-986, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38431913

RESUMO

PURPOSE: This study aimed to investigate the length change patterns of the native deep medial collateral ligament (dMCL) and potential anteromedial reconstructions (AMs) that might be added to a reconstruction of the superficial MCL (sMCL) to better understand the control of anteromedial rotatory instability (AMRI). METHODS: Insertion points of the dMCL and potential AM reconstructions were marked with pins (tibial) and eyelets (femoral) in 11 cadaveric knee specimens. Length changes between the pins and eyelets were then tested using threads in a validated kinematics rig with muscle loading of the quadriceps and iliotibial tract. Between 0° and 100° knee flexion, length change pattern of the anterior, middle and posterior part of the dMCL and simulated AM reconstructions were analysed using a rotary encoder. Isometry was tested using the total strain range (TSR). RESULTS: The tibiofemoral distance of the anterior dMCL part lengthened with flexion (+12.7% at 100°), whereas the posterior part slackened with flexion (-12.9% at 100°). The middle part behaved almost isometrically (maximum length: +2.8% at 100°). Depending on the femoral position within the sMCL footprint, AM reconstructions resulted in an increase in length as the knee flexed when a more centred position was used, irrespective of the tibial attachment position. Femoral positioning in the posterior aspect of the sMCL footprint exhibited <4% length change and was slightly less tight in flexion (min TSR = 3.6 ± 1.5%), irrespective of the tibial attachment position. CONCLUSION: The length change behaviour of potential AM reconstructions in a functionally intact knee is mainly influenced by the position of the femoral attachment, with different tibial attachments having a minimal effect on length change. Surgeons performing AM reconstructions to control AMRI would be advised to choose a femoral graft position in the posterior part of the native sMCL attachment to optimise graft length change behaviour. Given the high frequency of MCL injuries, sufficient restoration of AMRI is essential in isolated and combined ligamentous knee injuries. LEVEL OF EVIDENCE: There is no level of evidence as this study was an experimental laboratory study.


Assuntos
Ligamentos Colaterais , Traumatismos do Joelho , Humanos , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiologia , Fêmur/cirurgia , Tíbia/cirurgia , Fenômenos Biomecânicos , Amplitude de Movimento Articular/fisiologia , Cadáver
20.
Knee Surg Sports Traumatol Arthrosc ; 32(4): 953-962, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38444096

RESUMO

PURPOSE: The purpose of this study was to investigate the influence of increasing the tibial boundaries in functional alignment on femoral component orientation in total knee arthroplasty (TKA). METHODS: A retrospective review of a database of robotic-assisted TKAs using a digital joint tensioning device was performed (BalanceBot®; Corin). A total of 692 TKAs with correctable deformity were included. Functional alignment with a tibia-first balancing technique was simulated by performing an anatomic tibial resection to recreate the native medial proximal tibial angle within certain boundaries (A, 87-90°; B, 86-90°; C, 84-92°), while accounting for wear. After balancing the knee, the resulting amount of femoral component outliers in the coronal and axial plane was calculated for each group and correlated to the coronal plane alignment of the knee (CPAK) classification. RESULTS: The proportion of knees with high femoral component varus (>96°) or valgus (<87°) alignment increased from 24.5% (n = 170) in group A to 26.5% (n = 183) in group B and 34.2% (n = 237) in group C (p < 0.05). Similarly, more knees with high femoral component external rotation (>6°) or internal rotation (>3°) were identified in group C (33.4%, n = 231) than in group B (23.7%, n = 164) and A (18.4%, n = 127) (p < 0.05). There was a statistically significant (p < 0.01) overall increase in knees with both femoral component valgus <87° and internal rotation >3° from group A (4.0%, n = 28) to B (7.7%, n = 53) and C (15.8%, n = 109), with CPAK type I and II showing a 12.9- and 2.9-fold increase, respectively. CONCLUSION: Extending the tibial boundaries when using functional alignment with a tibia-first balancing technique in TKA leads to a statistically significant higher percentage of knees with a valgus lateral distal femoral angle < 87° and >3° internal rotation of the femoral component, especially in CPAK type I and II. LEVEL OF EVIDENCE: Level IV.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Tíbia/cirurgia , Articulação do Joelho/cirurgia , Fêmur/cirurgia , Estudos Retrospectivos , Osteoartrite do Joelho/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...